- Body Inside Diameter
- 0.5000 inches minimum and 0.5015 inches maximum
- Body Outside Diameter
- 0.6410 inches minimum and 0.6420 inches maximum
- Corner Shape
- round center flange left body corner
- Corner Shape
- square center flange outside left corner
- Corner Shape
- square center flange outside right corner
- Corner Shape
- square center flange right body corner
- Corner Shape
- square outside left corner
- Corner Shape
- square inside left corner
- Corner Shape
- square inside right corner
- Corner Shape
- square outside right corner
- End To Flange Distance
- 0.0520 inches minimum and 0.0570 inches maximum
- Flange Outside Diameter
- 1.2500 inches nominal
- Flange Width
- 0.0450 inches minimum and 0.0500 inches maximum
- Hardness Rating
- 34.0 rockwell c minimum and 38.0 rockwell c maximum overall
- Left End Body Diameter
- 0.7400 inches minimum and 0.7600 inches maximum
- Overall Length
- 0.6770 inches minimum and 0.6820 inches maximum
- Material Document And Classification
- 414ds120-7,77272 mfr ref single material response outer layer
- Material Document And Classification
- ams 5659 assn std single material response inner layer
- Material
- plastic outer layer
- Material
- steel inner layer
- Right End Body Diameter
- 0.6410 inches minimum and 0.6420 inches maximum
- Special Features
- liner od of body and right side of flange bonding agent and liner shallnot be affected by mil-h-5606/mil-h-83282 hydraulic fluid
- Style Designator
- solid, external flange
- Surface Finish
- 125.0 microinches left end surface of body and flange
- Surface Finish
- 63.0 microinches inside diameter surface of body
- Surface Treatment Document And Classification
- bac 5751,81205 mfr ref single treatment response inner layer
- Surface Treatment
- passivate inner layer
- Test Data Document
- "81205-bac-5424 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."